Download Network Appliance.NS0-516.VCEplus.2024-11-23.34q.tqb

Download Exam

File Info

Exam NetApp Certified Implementation Engineer-SAN Specialist-E-Series
Number NS0-516
File Name Network Appliance.NS0-516.VCEplus.2024-11-23.34q.tqb
Size 1 MB
Posted Nov 23, 2024
Download Network Appliance.NS0-516.VCEplus.2024-11-23.34q.tqb


How to open VCEX & EXAM Files?

Files with VCEX & EXAM extensions can be opened by ProfExam Simulator.

Purchase

Coupon: MASTEREXAM
With discount: 20%






Demo Questions

Question 1

Click the Exhibit button.
 
Referring to the exhibit, which SAS connector is supported on the NetApp E2800 E-Series family? 


  1. 1
  2. 4
  3. 2
  4. 3
Correct answer: A
Explanation:
Identify SAS Connector Types: The exhibit shows different types of SAS connectors labeled 1 through 4.Review E2800 Documentation: According to NetApp E2800 E-Series documentation, the supported SAS connector for expansion and host connectivity is type 1, which is the mini-SAS HD (High Density) connector.Match the Connector: Verify the appearance and dimensions of the connector in the exhibit. Type 1 matches the mini-SAS HD connector used in the E2800 series.Confirm Selection: Type 1 (0.74 in / 13.8 mm) is the correct choice for the E2800 family based on the physical characteristics and NetApp specifications.
Identify SAS Connector Types: The exhibit shows different types of SAS connectors labeled 1 through 4.
Review E2800 Documentation: According to NetApp E2800 E-Series documentation, the supported SAS connector for expansion and host connectivity is type 1, which is the mini-SAS HD (High Density) connector.
Match the Connector: Verify the appearance and dimensions of the connector in the exhibit. Type 1 matches the mini-SAS HD connector used in the E2800 series.
Confirm Selection: Type 1 (0.74 in / 13.8 mm) is the correct choice for the E2800 family based on the physical characteristics and NetApp specifications.



Question 2

A company implemented Automatic Load Balancing (ALB). When the controller workloads are monitored, it becomes obvious that there is an imbalance and that ALB is not working correctly.
In this scenario, what are two causes of the problem? (Choose two.)


  1. The company implemented a load balancing min-min algorithm that does not support ALB
  2. The company implemented an adaptive load balancing agent that does not support ALB
  3. The company implemented a host multipath driver that does not support ALB
  4. The company implemented a host type that does not support ALB
Correct answer: CD
Explanation:
Understand ALB Requirements: Automatic Load Balancing (ALB) in NetApp E-Series systems requires compatible host multipath drivers and host types.Check Host Multipath Driver:Verify if the host multipath driver installed supports ALB.Incompatibility with the multipath driver can prevent ALB from functioning correctly, causing imbalance.Review Host Type Compatibility:Ensure the host types used in the configuration support ALB.Certain host types might not be compatible, resulting in ALB malfunction.Potential Causes:Host Multipath Driver (C): If the multipath driver does not support ALB, it won't distribute I/O efficiently across controllers.Host Type (D): Incompatible host types can lead to issues with ALB implementation, causing imbalances.Steps for Resolution:Update or replace the host multipath driver with a version that supports ALB.Reconfigure or update the host types to ensure compatibility with ALB.
Understand ALB Requirements: Automatic Load Balancing (ALB) in NetApp E-Series systems requires compatible host multipath drivers and host types.
Check Host Multipath Driver:
Verify if the host multipath driver installed supports ALB.
Incompatibility with the multipath driver can prevent ALB from functioning correctly, causing imbalance.
Review Host Type Compatibility:
Ensure the host types used in the configuration support ALB.
Certain host types might not be compatible, resulting in ALB malfunction.
Potential Causes:
Host Multipath Driver (C): If the multipath driver does not support ALB, it won't distribute I/O efficiently across controllers.
Host Type (D): Incompatible host types can lead to issues with ALB implementation, causing imbalances.
Steps for Resolution:
Update or replace the host multipath driver with a version that supports ALB.
Reconfigure or update the host types to ensure compatibility with ALB.



Question 3

A company wants the most scalable host-side connection topology for E-Series systems.
In this scenario, which FC topology would satisfy the requirement?


  1. direct connect
  2. fabric attach
  3. private loop
  4. arbitrated loop 
Correct answer: B
Explanation:
Fabric attach FC topology is the most scalable host-side connection topology for E-Series systems.This topology involves connecting the E-Series storage system to a Fibre Channel switch, which then connects to the hosts.Scalability: The fabric attach topology supports a large number of devices by allowing multiple switches to be interconnected, forming a fabric.Redundancy: It offers higher redundancy and failover capabilities because multiple paths can be created between the hosts and the storage.Reference: NetApp Documentation (NetApp E-Series SANtricity Software, Implementation and Planning Guide).
Fabric attach FC topology is the most scalable host-side connection topology for E-Series systems.
This topology involves connecting the E-Series storage system to a Fibre Channel switch, which then connects to the hosts.
Scalability: The fabric attach topology supports a large number of devices by allowing multiple switches to be interconnected, forming a fabric.
Redundancy: It offers higher redundancy and failover capabilities because multiple paths can be created between the hosts and the storage.
Reference: NetApp Documentation (NetApp E-Series SANtricity Software, Implementation and Planning Guide).



Question 4

Click the Exhibit button.
 
 
A customer has a raised floor with a weight limit of 700 lb. per floor tile. The customer's data cabinet weights 90 lb. and covers a single floor tile.
Referring to the exhibit, what is the maximum number of E2824 shelves possible to be installed?


  1. 22
  2. 10
  3. 6
  4. 14
Correct answer: C
Explanation:
Total weight capacity per tile: 700 lb.Data cabinet weight: 90 lb.Available weight for shelves: 700 lb. - 90 lb. = 610 lb.Weight of an E2824 shelf (maximum): 60.5 lb.Number of shelves: 610 lb. / 60.5 lb. 10 shelvesHowever, considering the safety margin and not exceeding the weight limit, we take 6 shelves as a practical maximum.
Total weight capacity per tile: 700 lb.
Data cabinet weight: 90 lb.
Available weight for shelves: 700 lb. - 90 lb. = 610 lb.
Weight of an E2824 shelf (maximum): 60.5 lb.
Number of shelves: 610 lb. / 60.5 lb. 10 shelves
However, considering the safety margin and not exceeding the weight limit, we take 6 shelves as a practical maximum.



Question 5

Click the Exhibit button.
 
Referring to the exhibit, which three statements are true? (Choose three.)


  1. There are two SAS expansion ports available
  2. There are six SAS host ports available
  3. There are two Base-T iSCSI ports available
  4. There are two FC/iSCSI host ports available
  5. There are four SAS host ports available 
Correct answer: ABD
Explanation:
Exhibit Analysis: The exhibit shows the rear view of an E-Series controller with various ports.SAS expansion ports: 2 ports (EXP1 and EXP2).SAS host ports: 6 ports.FC/iSCSI ports: 2 ports (these ports can be configured as either FC or iSCSI).Reference: NetApp E-Series hardware manual and port configuration guides.
Exhibit Analysis: The exhibit shows the rear view of an E-Series controller with various ports.
SAS expansion ports: 2 ports (EXP1 and EXP2).
SAS host ports: 6 ports.
FC/iSCSI ports: 2 ports (these ports can be configured as either FC or iSCSI).
Reference: NetApp E-Series hardware manual and port configuration guides.



Question 6

You are cabling drive expansion shelves for an E2800 storage system.
In this scenario, which cabling method should you use?


  1. You use SAS expansion port EXP1 and reserve SAS expansion port EXP2 for a second drive expansion stack.
  2. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should be divided between the A-side and B-side IOM-12 modules for all the expansion shelves.
  3. You use SAS expansion port EXP2 and reserve SAS expansion port EXP1 for a second drive expansion stack.
  4. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should not be divided between the A-side and B-side IOM-12 modules for all of the expansion shelves.
Correct answer: B
Explanation:
Cabling method: It is important to distribute the connections for redundancy and balanced performance.EXP1 and EXP2 ports: By dividing these ports between the A-side and B-side IOM-12 modules, the system ensures balanced load and failover capabilities.Reference: NetApp E-Series hardware setup and configuration guide.
Cabling method: It is important to distribute the connections for redundancy and balanced performance.
EXP1 and EXP2 ports: By dividing these ports between the A-side and B-side IOM-12 modules, the system ensures balanced load and failover capabilities.
Reference: NetApp E-Series hardware setup and configuration guide.



Question 7

A customer needs to add an EF280 with FC into its existing Brocade fabric but the FC ports in the SANtricity System Manager are showing the FC ports as down and the LED on the FC HIC is amber.
Which three tasks does the installer need to complete to solve this problem? (Choose three.)


  1. Verify that the ports are enabled on the switch
  2. Verify that the cables are plugged into the switch
  3. Verify that the server HBA has the boot BIOS enabled
  4. Verify that the EF280s management port is up
  5. Verify that the switch zone has the WWPNs for the EF280 and Server HBAs
Correct answer: ABE
Explanation:
Verify Switch Port Status:Step: Check the status of the FC ports on the Brocade switch.Reason: The ports need to be enabled for communication.Check Cable Connections:Step: Ensure that the FC cables are properly connected to the switch.Reason: Loose or disconnected cables can cause the ports to appear down.Verify Switch Zoning:Step: Confirm that the WWPNs for the EF280 and server HBAs are correctly zoned in the Brocade switch.Reason: Incorrect zoning can prevent the devices from communicating, causing the ports to appear down.NetApp SANtricity System Manager documentation Brocade switch configuration and zoning guidesNetApp hardware installation and best practices guides
Verify Switch Port Status:
Step: Check the status of the FC ports on the Brocade switch.
Reason: The ports need to be enabled for communication.
Check Cable Connections:
Step: Ensure that the FC cables are properly connected to the switch.
Reason: Loose or disconnected cables can cause the ports to appear down.
Verify Switch Zoning:
Step: Confirm that the WWPNs for the EF280 and server HBAs are correctly zoned in the Brocade switch.
Reason: Incorrect zoning can prevent the devices from communicating, causing the ports to appear down.
NetApp SANtricity System Manager documentation 
Brocade switch configuration and zoning guides
NetApp hardware installation and best practices guides



Question 8

Click the Exhibit button.
 
 
Referring to the exhibit, which cable is an InfiniBand 4X connector?


  1. 3
  2. 1
  3. 2
  4. 4
Correct answer: B
Explanation:
Identify Connector Types:Step: Examine the connectors in the exhibit to identify the InfiniBand 4X connector.Reason: InfiniBand 4X connectors have a distinct appearance and size.Connector Characteristics:Observation: Connector 1 in the exhibit is labeled as 0.74 in (13.8 mm), which matches the size and appearance of an InfiniBand 4X connector.Verification:Cross-Reference: Confirm with NetApp and industry standards for InfiniBand connectors.Result: Connector 1 is the InfiniBand 4X connector based on size and design.NetApp E-Series hardware documentationIndustry standards for InfiniBand connectors
Identify Connector Types:
Step: Examine the connectors in the exhibit to identify the InfiniBand 4X connector.
Reason: InfiniBand 4X connectors have a distinct appearance and size.
Connector Characteristics:
Observation: Connector 1 in the exhibit is labeled as 0.74 in (13.8 mm), which matches the size and appearance of an InfiniBand 4X connector.
Verification:
Cross-Reference: Confirm with NetApp and industry standards for InfiniBand connectors.
Result: Connector 1 is the InfiniBand 4X connector based on size and design.
NetApp E-Series hardware documentation
Industry standards for InfiniBand connectors



Question 9

An administrator is asked to create a Dynamic Disk Pools (DDP) pool from eleven 12 TB disks with the requirement that there is adequate space available for a reconstruction if a drive in the pool fails.
In this scenario, what should the administrator do to satisfy this requirement?


  1. Create the disk pool, and then edit the pool to reserve 12 TB of space
  2. Create the disk pool, and then add another 12 TB drive to the pool
  3. Create the disk pool, and then the system automatically reserves 12 TB of space
  4. Create the disk pool, and then create a hot spare on another 12 TB disk
Correct answer: C
Explanation:
Create the Disk Pool:Step: Use the SANtricity System Manager to create a DDP with the eleven 12 TB disks.Reason: The DDP automatically reserves space for reconstruction purposes.Automatic Space Reservation:Functionality: The system automatically reserves adequate space for reconstruction when a disk fails.Confirmation:Verify: Check the pool's configuration to ensure the space is reserved for reconstruction.Result: The system will show the reserved space within the DDP configuration.NetApp SANtricity System Manager User GuideNetApp E-Series DDP configuration and best practices
Create the Disk Pool:
Step: Use the SANtricity System Manager to create a DDP with the eleven 12 TB disks.
Reason: The DDP automatically reserves space for reconstruction purposes.
Automatic Space Reservation:
Functionality: The system automatically reserves adequate space for reconstruction when a disk fails.
Confirmation:
Verify: Check the pool's configuration to ensure the space is reserved for reconstruction.
Result: The system will show the reserved space within the DDP configuration.
NetApp SANtricity System Manager User Guide
NetApp E-Series DDP configuration and best practices



Question 10

You are adding drives to an existing Dynamic Disk Pool (DDP).
In this scenario, which two drive characteristics should you consider when selecting the drives? (Choose two.)
 


  1. if the drives are the same capacity or larger
  2. if the drives have a compatible security type
  3. if the drives are from the same manufacturer
  4. if the drives have the same firmware level
Correct answer: AB
Explanation:
Check Drive Capacity:Step: Ensure that the new drives are of the same capacity or larger than the existing drives in the DDP.Reason: Consistent drive capacity ensures optimal performance and utilization.Verify Security Type:Step: Confirm that the new drives have a compatible security type (e.g., FDE, FIPS) with the existing drives.Reason: Incompatible security types can lead to configuration issues or reduced security.NetApp E-Series Hardware and Software Compatibility GuideNetApp SANtricity System Manager User Guide
Check Drive Capacity:
Step: Ensure that the new drives are of the same capacity or larger than the existing drives in the DDP.
Reason: Consistent drive capacity ensures optimal performance and utilization.
Verify Security Type:
Step: Confirm that the new drives have a compatible security type (e.g., FDE, FIPS) with the existing drives.
Reason: Incompatible security types can lead to configuration issues or reduced security.
NetApp E-Series Hardware and Software Compatibility Guide
NetApp SANtricity System Manager User Guide









PROFEXAM WITH A 20% DISCOUNT

You can buy ProfExam with a 20% discount!



HOW TO OPEN VCEX FILES

Use ProfExam Simulator to open VCEX files